Storage Battery Testing and Regeneration Instrument SF100

Item No.: SF100
Input Power: AC200V~245V50/60HZ
Applicable Batteries: 6V/8V/12V/16V/18V Lead-acid batteries
Charge Con-Voltage: 3.6V-23V
Discharge Cut-off Voltage: 2V-20V
Discharge Current: 0.5A-10A
Charge Current: 0.5A-6A
Operation Method: Panel
Description
SF100 is a professional battery performance testing instrument integrated with high precision capacity discharge test, ordinary three-stage charge, water-replenishing maintenance charge, pulse repair. It can set the voltage and current of charge and discharge by the user and has the function of auto charge-discharge cycling, The instrument also has the pulse repair function to repair the vulcanization of the battery, so that the battery capacity can be restored to normal levels, which can greatly prolong service life and extending the warranty time.

It's an essential instrument for battery performance testing & scheduled maintenance to prolong the service life of the batteries.


Applicable Batteries:
6V/8V/12V/16V/18V Lead-acid batteries, recommended capacity:<30 AH



Features:

- Instrument displays by LCD, each index is clear at a glance.
- The parameter setup and parameter switching are set and switched by a “START” switch and a “SET” knob. All parameters(voltage, current, mode) setting have the saving function.
- Intelligent speed fan can run continuously, delay the power-off of the fan, and blow-off the remaining heat.
- Polarity protection, anti-reverse connection, and so on.
- Each circuit is the independent module, no influence each other
- The instrument have simple mode and professional mode for choice to meet the different requirement of the user.
- Data protection startup: If the connection cables disconnected from the battery during the charging and discharging, after reconnecting the cables with the battery, press and hold the “Start” button to continue working.
- Power-off memory function.


Operation Modes:

10 operation modes
Mode Code Function
0 Enquire
1 Capacity Test
2 Typical Charging
3 Discharging→Idle→Charging
4 Charging→Idle→Discharging→Idle→Charging
5 Discharging→Idle→Charging→Idle→Discharging→Idle→Charging
6 Charging→Idle→Discharging→Idle→Charging→Idle→Discharging→Idle→Charging
7 Automatic Repair Mode:  Charging→Idle→Repair→Idle→Discharging→Idle→Charging
8 Pulse Repair Mode
9 Charging→Discharging
 


Technical Specification:
 
Model No.: SF100-5/6
Items Parameter
Input Voltage: AC 220 V± 10% 50 Hz / 60 Hz
Input Power: No-load: SF100-5 SF100-6
    70W 80W
  Full-load: SF100-5 SF100-6
    750W 900W
Applicable Battery Types: 6 V, 12 V, 16 V, 18V Storage Batteries
Functions: Charge
  Discharge
  Auto cycle charge and discharge
  Pulse repair
  Data record and inquire
Voltage Max. Charge Voltage: 23 V
  Min. Charge Voltage: 3.6 V
  Amplitude Of Adjustment: 0.1 V stepping
  Charge Voltage Tolerance: ± 0.5 V
  Max. Discharge Cut-off Voltage: 20 V
  Min. Discharge Cut-off Voltage: 2 V
  Amplitude Of Adjustment: 0.1 V stepping
  Discharge Voltage Tolerance: ± 0.03 V
Current Charge Current: 0.5 A – 6 A adjustable
  Amplitude Of Adjustment: 0.1 A stepping
  Charge Current Tolerance: ± 0.1 A
  Discharge Current: 0.5 A – 10 A adjustable
  Amplitude Of Adjustment: 0.1 A stepping
  Discharge Current Tolerance: ± 0.03 A
Charge Charge Mode: Constant current & voltage charge
  Cut-off Conditions: When reaching high constant voltage, the system will automatically switch to trickle charge after charging for 3.5 hours or the charging current is less than 0.3A
Discharge Discharge Mode: Constant current discharge
  Cut-off Conditions: Voltage
Cycle Cycle Mode 1 DSCH → IDLE→CHG
  Cycle Mode 2 CHG→IDLE→DSCH→IDLE→CHG
  Cycle Mode 3 DSCH→IDLE→CHG→IDLE→DSCH→IDLE →CHG
  Cycle Mode 4 CHG→IDLE→DSCH→IDLE→CHG→IDLE →DSCH→IDLE→CHG 
  Cycle Mode 5 CHG →IDLE→DSCH
Pulse Repair  Pulse Current: 0.3 A
  Pulse Frequency: 500 Hz
  Time of Single Repair: 12 HRS
Protection: Power-down protection
  Reverse connection protection
  Over-temperature protection
  Over-voltage protection
  Short-circuit protection
IP Grade IP20
Channel Control Mode Independent control
High Voltage Insulation Between Channels AC1000V/2min Normal                                   
Data Display LCD
Operation Method Panel
Voltage & Current Test Sampling Five-core wires connection
Noise < 76 dB
Upper Computer Communication None
Communication Port None
Equipment Work Ambient Conditions
Operation Ambient Temperature 0 ℃ - 40 ℃
Storage Temperature -10 ℃ - 50 ℃
Operation Ambient Humidity ≤ 70 % RH (No condensation)
Storage Ambient Humidity ≤ 80 % RH (No condensation)

Illustrations



LCD Interface




Packing  Information:
Model No.: SF100-5 SF100-6
Product Size(L*W*H): 59.5*40*17 cm         71*40*17 cm         
Pcs/Ctn: 1 pcs/ctn 1 pcs/ctn
Package Size(L*W*H): 70.5*50*31 cm 82.5*50*31 cm
G.W.:  17.80 kgs 18.8 kgs
N.W.: 15.80 kgs 16.8 kgs
Let Us Bounce Into Your Inbox